| Available Pitches | 0/12 to 6/12, 7/12 to 12/12 |
| Part Numbers | 6DP-F6, 6DP-F12 |
| Diameter | 6" |
| Material | Galvalume |
| Construction | Triple-wall, all-fuel |
| Inner Liner | .016" 430 stainless steel |
| Intermediate Liner | .018" aluminized steel |
| Outer Wall | .018" galvanized steel |
| Insulation | Ceramic blanket plus ventilated air space |
| Connection Type | Twist-lock |
| Clearance to Combustibles | 2" |
| Listing | UL 103 HT (MH7399), ULC S629 |
| Continuous Flue Temperature | 1000°F |
| Chimney Fire Rating | 2100°F |
| Approved Fuels | Wood, oil, coal, gas |
Download the full manufacturer installation instructions before you begin. Installation must follow these instructions and your appliance manual to stay code compliant and keep the warranty valid.
Pitch is the rise over 12 inches of horizontal run. A roof that climbs 6 inches over 12 is a 6/12. If you are between ranges, measure rather than guess, since the wrong flashing will not seat flat.
Yes, always. The flashing sheds water off the roof surface and the storm collar seals the gap where the pipe passes through it. A flashing without a collar will leak.
A non-hardening sealant rated to 500°F at the collar. Standard roofing caulk will harden and crack from the heat cycling.
If your stove has a 6" flue outlet, yes. Wood stove manufacturers call for a chimney listed to UL 103 HT (2100°F), which is exactly what DuraPlus carries. Drolet, for example, specifies a 6" HT type chimney in its manuals without naming a brand.
No. Class A chimney systems use proprietary locking joints and are listed as complete systems, so DuraPlus will not join to DuraTech, Selkirk or Ventis. Everything from the ceiling support box to the cap must be DuraPlus.
They are not interchangeable. Black stovepipe is connector pipe for the exposed run from stove to ceiling only and cannot pass through a ceiling, wall or roof. DuraPlus is Class A insulated chimney, which carries the flue through the building and outside.
Two inches of clearance to any combustible, the entire length of the run. Where it passes through an attic you also need an attic insulation shield. Never pack insulation against the chimney even though the outer wall runs cool.