The CB-4012-SS stainless steel wall mount secures a Grizzly mini wood stove and complements its appearance. For non-certified recreational setups, shielding can reduce clearances as specified in the stove and mount instructions. Certified units require 18 inches of clearance from the outside surface of the flue pipe to combustibles; this clearance generally cannot be reduced. Position the stove and mount to maintain the required pipe clearance.
For non-certified recreational setups, provides shielding between the stove and the mounting surface. Follow the stove and mount instructions for permitted clearance reductions.
Dimensions
4 3/16"(10.64cm) from wall to center of flue collar
16 5/8"(42.2cm) wide
51 7/8"(131.7cm) tall when flue shield is fully extended
39 3/8"(100cm) tall when flue shield is completely reduced
For non-certified recreational setups, provide a 14" lateral stove clearance from a surface left or right of the stove unless a Side Shield CB-2216-SS is used as specified in the installation instructions.
For non-certified setups, maintain a 1" air gap between the bottom plate and the surface below, as specified in the mount instructions. For certified units, follow the certified stove manual and maintain the separate pipe-clearance requirement.
Includes 37" of flue shielding. For non-certified setups that require pipe shielding, the flue shield must run behind the pipe along the entire wall-facing run. If you have more than 37" of flue pipe inside, you will need enough Flue shield extensions CB-2215-SS-30 to cover the rest of the way.
Comes with side guards to prevent heat from spilling onto the surface it is mounted to.